DOI: https://dx.doi.org/10.18203/2349-2902.isj20222233
Published: 2022-08-26

Syringe needle-cap use as novel, static, uni-planar or bi-planar, mini-external fixator for treatment of intra-condylar phalangeal fractures

Vijay Kumar Pandey, Rakesh Kaundal

Abstract


Background: Comminuted intra-articular phalanx fractures are complicated injuries often treated with external fixation. Syringe needle- cap can be an excellent mini-external fixators because they are radiolucent, readily available, inexpensive, simple, safe and easy to use. Our cases received a novel treatment in the form a syringe needle-cap/mini external fixator that was originally placed in static mode for 3 weeks and then later removed in OPD visit to a dynamic-mode of ROM to allow rehabilitation of the PIPJ/DIPJ. Our cases illustrates the power and utility of this ‘static’ uniplanar or biplanar stable technique to treat intra-condylar phalanx  fractures and achieved good functional recovery of finger.

Methods: This was a prospective case study covering period from January 2021 to May 2022 at department of plastic surgery, Command Hospital, Chandimandir, Panchkula, Haryana, India. 10 young male patients were presented with intra-articular fractures of phalanx. All patients had undergone pre-operative and post procedure X-rays for evaluation. A static external fixator consisting of a uniplanar or biplanar 2 ml syringe needle-cap and 0.8mm small size (3-4 cm) Kirschner wires as an optimal fixator across the fractured joint. K-wires were removed in OPD visit after 3 weeks to dynamize the ROM of affected joint of finger post-operatively.

Results: 10 male patients were studied with average age of 28 years. 06 of them are intra-condylar fractures at PIP joints and rest are intra-articular fractures. After 3 weeks, we removed this fixator device and started controlled physiotherapy. End results notified in our study were achievement of good functional recovery of finger ROM at 3 months follow up.

Conclusions: Syringe needle-cap use as mini-external fixation should be considered as a novel tool in the treatment of comminuted intra-articular phalangeal fracture.


Keywords


Syringe needle-cap, Intra-condylar comminuted unstable fractures, Kirschner’s wire

Full Text:

PDF

References


Shehadi SI. External fixation of metacarpal and phalangeal fractures. J Hand Surg Am. 1991;16(3):544-50.

Hastings H, Ernst JM. Dynamic external fixation for fractures of the proximal interphalangeal joint. Hand Clin. 1993;9(4):659-74.

Kasparyan NG, Hotchkiss RN. Dynamic skeletal fixation in the upper extremity. Hand Clin. 1997;13(4):643-63.

Krakauer JD, Stern PJ. Hinged device for fractures involving the proximal interphalangeal joint. Clin Orthop Relat Res. 1996;(327):29-37.

Stern PJ, Roman RJ, Kiefhaber TR, McDonough JJ. Pilon fractures of the proximal interphalangeal joint. J Hand Surg Am. 1991;16(5):844-50.

Suzuki Y, Matsunaga T, Sato S, Yokoi T. The pins and rubbers traction system for treatment of comminuted intraarticular fractures and fracture-dislocations in the hand. J Hand Surg Br. 1994;19(1):98-107.

Walter FL, Papandrea RF. A mini external fixator for hand and finger fractures constructed from readily available materials. Tech Hand Up Extrem Surg. 2011;15(4):215-8.

Dailiana Z, Agorastakis D, Varitimidis S, Bargiotas K, Roidis N, Malizos KN. Use of a mini-external fixator for the treatment of hand fractures. J Hand Surg Am. 2009;34(4):630-6.

Babu V, Baskaran K, Kocialkowski A. External fixation of finger fractures made simple. Acta Orthop Belg. 2005;71(3):347-8.

McCulley SJ, Hasting C. External fixator for the hand: a quick, cheap and effective method. J R Coll Surg Edinb. 1999;44(2):99-102.

Namazi H, Mozaffarian K. A novel external fixator of the hand: a practice pearl. Tech Hand Up Extrem Surg. 2013;17(1):57-9.

Namazi H, Mozaffarian K. A novel external fixator of the hand: a practice pearl. Tech Hand Up Extrem Surg. 2013;17(1):57-9.

Tank PM, Patel NB, Patel V. Simple low cost static externalfixators for phalangeal fractures of the hand. Int J Orthop Sci. 2018;4:714-20.

Farag HE, Essawy OM. Fifth metacarpal fractures: treatment by low-cost syringe fixator. Al-Azhar Assiut Med J. 2015;13:134-8.

Shah J, Rahman O, Ahmed R. Phalangeal fractures: managementby cost-effective syringe fixators. J Rawalpindi Med College. 2015;19:133-5.